Sign In | Join Free | My isp.org.cn
China Changzhou DLX Alloy Co., Ltd. logo
Changzhou DLX Alloy Co., Ltd.
1. We are able to design and develop products based on customer needs, and meet customer requirements by providing appropriate engineering drawings or samples. 2. We can provide the product within one
Verified Supplier

5 Years

Home > Mineral Insulated Cable >

INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable

Changzhou DLX Alloy Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable

Brand Name : DLX

Model Number : Type S MI Thermocouple cable

Place of Origin : China

MOQ : 500

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 100000 meters per month

Delivery Time : 5-21 days

Packaging Details : Spool package with Carton box, Coil package with polybag

Product name : MI Thermocouple Wire

Color : white, Red, Yellow and etc

Certificate : ISO9001

Grade : SP/NN, Extension Grade SPX/SNX

Positive : Platinum Rhodium

Negative : Platinum

Contact Now

INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable

  • Type S Thermocouple MI CABLE

MI thermocouple cable is used to insulate thermocouple wires from one another and from the metal sheath that surrounds them. MI Cable has two (or four when duplex) thermocouple wires running down the middle of the tube. The tube is then filled with magnesium oxide powder and compacted to ensure the wires are properly insulated and separated. Mineral insulated cable helps to protect the thermocouple wire from corrosion and electrical interference MI themocouple cable.


Advantages:
1, improve the mechanical and physical properties of the measuring lines of thermocouple.
2, reduce the cost of measuring lines

Within certain range of temperature, a pair of insulating wires used in the applicable thermocouple which has the same feature is called compensation wire. When correctly connected with the applicable thermocouple, it will extend the reference end of thermocouple to a place away from heat or with constant temperature.


  • Thermocouple Wire
Code Wires component of the thermocouple
+Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)
B Platinum Rhodium-30% Platinum Rhodium-6%
R Platinum Rhodium-13% Platinum
S Platinum Rhodium-10% Platinum

  • ​Standards
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044


  • Size range

Dia(mm): 0.5 to 12.7 mm.

  • Parameter
Out Sheath(mm) Core wire Dia.(mm) Sheath Material Length(m)
Our Dia. WallThickness K,N,E,J,T type S,R,B types K,N types E,J,T types S,R type B type
0.5 0.05-0.1 0.08-0.12 ---

SS304

SS321

SS316

SS310

INCL600

SS304

SS321

SS316

INCL600

INCL800

INCL600

INCL800

500
1 0.1-0.2 0.15-0.2 --- 300
1.5 0.15-0.25 0.23-0.3 --- 200
1.6 0.16-0.26 0.26-0.36 --- 200
2 0.25-0.35 0.4-0.5 0.25-0.3 180
3 0.38-0.48 0.5-0.6 0.30-0.4 80
3.2 0.48-0.58 0.58-0.68 0.30-0.4 75
4 0.52-0.62 0.6-0.7 0.35-0.4 70
4.8 0.73-0.83 0.75-0.85 0.4-0.45 40
5 0.78-0.88 0.80-0.90 0.4-0.45 40
6 0.98-1.08 0.90-1.1 0.45-0.5 30
6.4 1.05-1.15 1.02-1.12 0.45-0.5 30
8 1.30-1.44 1.30-1.40 0.45-0.5 20
12.7 1.75-1.90 1.92-2.05 --- 10

  • Type and Sheath table

Product name code type sheath material out Dia.(mm) Temperature
Ni Cr-Ni-Si KK K SS304 0.5-1.0 400
SS321 1.5-3.2 600
SS316 4.0-8.0 800
0.5-1.0 500
SS310 1.5-3.2 800
INCL600 4.0-6.4 900
8.0-12.7 1000
NICROBELL 4.0-6.4 900
8.0-12.7 1200
Ni Cr Si-Ni Si NK N SS304 0.5-1.0 400
SS321 1.5-3.2 600
SS316 4.0-8.0 800
0.5-1.0 500
SS310 1.5-3.2 800
INCL600 4.0-6.4 900
8.0-12.7 1000
NICRPBELL 4.0-6.4 900
8.0-12.7 1200
Ni Cr-Constantan EK E SS304 0.5-1.0 400
SS321 1.5-3.2 500
SS316 4.0-8.0 800
Fe-Constantan JK J SS304 1.0 300
SS321 1.5-3.2 500
SS316 1.0-8.0 800
Cu-Constantan TK T SS304 -200-100
SS321 100-200
SS316 100-350

INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable
INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable
INCL 800 0.5mm Red Type S MI NN mineral insulated heating cableINCL 800 0.5mm Red Type S MI NN mineral insulated heating cable


Product Tags:

INCL 800 Mineral Insulated Cable

      

0.5mm Mineral Insulated Thermocouple

      

NN Mineral Insulated Cable

      
Cheap INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable wholesale

INCL 800 0.5mm Red Type S MI NN mineral insulated heating cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changzhou DLX Alloy Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)